Display |
Action |
Response |
|
Press
MENU
Press ENTER
|
1) Press
MENU, if necessary,
until the "COM
OPTN" prompt
appears.
2) Display
advances to "Communication
Parameters" submenu. |
|
Press
MENU |
IF
THE COMMUNICATION
OPTION IS NOT
INSTALLED, THE
CONTROLLER WILL
SHOW "not_InSt"
Press MENU, if
you receive the
"not installed"
message and advance
to the "Remote
Set Point" menu.
|
|
Press ENTER |
COMMUNICATION
PARAMETERS SUBMENU:
Display shows
"communication
parameters" prompt.
3) Display
advances to "BAUD"
submenu. |
|
Press
ENTER
Press MAX
Press ENTER
|
BAUD
SUBMENU:
4) Display
flashes previous
selection for
"BAUD" value.
5) Scroll
through the available
selections: 300,
600, 1200, 2400,
4800, 9600, 19.2K.
6) Display
flashes "strd"
message and advances
to "Parity" submenu.
|
|
Press
ENTER
Press MAX
Press ENTER |
PARITY
SUBMENU:
7) Display
flashes previous
selection for
"Parity".
8) Scroll
through the available
selections: NO,
ODD, EVEN.
9) Display
flashes "strd"
message and advances
to "Data Bit"
submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
DATA
BIT SUBMENU:
7) Display
flashes previous
selection for
"Data Bit".
8) Scroll
through the available
selections: 7
BIT, 8 BIT.
9) Display
flashes "strd"
message and advances
to "Stop Bit"
submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
STOP
BIT SUBMENU:
7) Display
flashes previous
selection for
"Stop Bit".
8) Scroll
through the available
selections: 1
BIT, 2 BIT.
9) Display
flashes "strd"
message and advances
to "BUS FORMAT"
submenu. |
|
Press
ENTER |
BUS
FORMAT SUBMENU:
Display shows
"bus frPt" prompt.
10) Display
advances to "Check
Sum" submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
CHECK
SUM SUBMENU:
Not Installed
(always set this
parameter to
"no")
11) Display
flashes previous
selection for
"Check Sum".
12) Scroll
through the available
selections:
NO, YES.
13) Display
flashes "strd"
message and advances
to "Line Feed"
submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
LINE
FEED SUBMENU:
14) Display
flashes previous
selection for
"Line Feed".
15) Scroll
through the available
selections:
NO, YES.
16) Display
flashes "strd"
message and advances
to "ECHO" submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
ECHO
SUBMENU:
17) Display
flashes previous
selection for
"ECHO".
18) Scroll
through the available
selections:
NO, YES.
19) Display
flashes " strd
" message and
advances to "Standard"
submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
STANDARD
SUBMENU:
20) Display
flashes previous
selection for
"Standard".
21) Scroll
through the available
selections:
232C, 485.
22) Display
flashes " strd
" message and
advances to "Mode"
submenu. |
|
Press ENTER
Press MAX
Press ENTER |
MODE
SUBMENU:
23) Display
flashes previous
selection for
"Mode".
24) Scroll
through the available
selections:
CMND, CONT (command,
continuous)
25) Display
flashes "strd"
message and advances
to "Separation"
submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
SEPARATION
SUBMENU:
26) Display
flashes previous
selection for
"Separation".
27) Scroll
through the available
selections:
SPCE, CR (space,
carriage return)
28) Display
flashes "strd"
message and advances
to "Data Format"
submenu. |
|
Press ENTER |
DATA
FORMAT SUBMENU:
Display shows
"dAtA frPt" prompt.
This menu is
applicable for
continuous mode
of RS232 communication
32) Display
advances to "Status"
submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
STATUS
SUBMENU:
33) Display
flashes previous
selection for
"Status" (alarm
status).
34) Scroll
through the available
selections: NO,
YES
35) Display
flashes "strd"
message and advances
to "Reading"
submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
READING
SUBMENU:
36) Display
flashes previous
selection for
"Reading".
37) Scroll
through the available
selections: NO,
YES
38) Display
flashes "strd"
message and advances
to "Peak" submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
PEAK
SUBMENU:
39) Display
flashes previous
selection for
"Peak".
40) Scroll
through the available
selections: NO,
YES
41) Display
flashes "strd"
message and advances
to "Valley" submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
VALLEY
SUBMENU:
42) Display
flashes previous
selection for
"Valley".
43) Scroll
through the available
selections: NO,
YES
44) Display
flashes "strd"
message and advances
to "Unit" submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
UNIT
SUBMENU:
45) Display
flashes previous
selection for
"Unit".
46) Scroll
through the available
selections: NO,
YES
47) Display
flashes "strd"
message and advances
to "ID" submenu. |
|
Press
ENTER
Press MAX
Press ENTER |
ID
SUBMENU:
48) Display
flashes previous
selection for
"Reading".
49) Scroll
through the available
selections: NO,
YES
50) Display
flashes "strd"
message and advances
to "Address Setup"
submenu. |
|
Press ENTER |
ADDRESS
SETUP SUBMENU:
Display shows
"addr st.up"
prompt. This
menu is applicable
to the RS 485
option only
51) Display
advances to "Address
Value" (0000
to 0199) submenu. |
|
Press
ENTER
Press MAX/MIN
Press ENTER |
ADDRESS
VALUE SUBMENU:
52) Display
flashes 1st digit
of previous address
value.
53) Enter
new address value.
54) Display
flashes "strd"
message and advances
to "Transmit
Time" submenu.
If no change
press ômenuö
to go on. |
|
Press ENTER |
TRANSMIT
TIME SUBMENU:
Display shows
"tr.ti st.up"
prompt. This
menu is applicable
if continuous
mode was selected.
55) Display
advances to "Transmit
Time Value" submenu. |
|
Press
ENTER
Press MAX/MIN
Press ENTER |
TRANSIT
TIME VALUE SUBMENU:
56) Display
flashes 1st digit
of previous transmit
time in seconds.
57) Enter
new transmit
time, e.g. 0030
will send every
30 seconds the
data in continuous
mode.
58) Display
flashes "strd"
message and advances
to "Remote Setpoint"
menu. If no change
press ômenuö
to go on. |